Performance characteristics
Sample type |
Serum, plasma, animal tissue, cells |
Sensitivity |
0.12 μmol/L |
Detection range |
0.12-30 μmol/L |
Detection method |
Fluorescence method |
Assay type |
Quantitative |
Assay time |
20 min |
Precision |
Average inter-assay CV: 7.300%Average intra-assay CV: 1.700% |
Other instruments required |
Micropipettor, Vortex mixer, Centrifuge |
Storage |
-20℃ |
Valid period |
12 months |
Dilution of sample
It is recommended to take 2~3 samples with expected large difference to do pre-experiment before formal experiment and dilute the sample according to the result of the pre-experiment and the detection range (0.12-30 μmol/L).
The recommended dilution factor for different samples is as follows (for reference only):
Sample type
|
Dilution factor
|
Human serum
|
100-300
|
Rat serum
|
100-300
|
Mouse plasma
|
100-300
|
Rabbit serum
|
100-300
|
10% Rat liver tissue homogenate
|
50-150
|
10% Mouse kidney tissue homogenate
|
50-200
|
10% Rat brain tissue homogenate
|
200-400
|
10% Rat spleen tissue homogenate
|
50-200
|
Jukat cells
|
20-50
|
Note: The diluent is reagent 1.